4MDK

Cdc34-ubiquitin-CC0651 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyCCD
Collection date2011-10-11
DetectorADSC QUANTUM 315
Wavelength(s)0.97919
Spacegroup nameP 1
Unit cell lengths55.403, 72.220, 75.912
Unit cell angles71.89, 79.63, 81.61
Refinement procedure
Resolution44.627 - 2.610
R-factor0.2069
Rwork0.204
R-free0.25900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)PDB ENTRIES 2OB4 AND 3A33
RMSD bond length0.008
RMSD bond angle1.264
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8.2_1309))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.640
High resolution limit [Å]2.6007.0502.600
Rmerge0.0790.0440.457
Number of reflections31394
<I/σ(I)>13.734.31.2
Completeness [%]95.897.285.5
Redundancy2.22.21.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP729328% PEG3350, 0.1 M HEPES, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218500