4MD4
Immune Receptor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-11-25 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.95369 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 67.091, 182.580, 77.539 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.077 - 1.950 |
R-factor | 0.167 |
Rwork | 0.165 |
R-free | 0.20910 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 1.106 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 62.970 | 2.060 |
High resolution limit [Å] | 1.950 | 1.950 |
Rmerge | 0.122 | 0.457 |
Number of reflections | 34301 | |
<I/σ(I)> | 2.6 | |
Completeness [%] | 85.8 | |
Redundancy | 6.5 | 4.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.3 | 294 | 25% PEG 3350, 0.2M Potassium Nitrate, 0.1M Bis-Tris-Propane pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 294K |