4KPZ
Hin GlmU bound to a small molecule fragment
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-01-16 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1 |
Spacegroup name | H 3 2 |
Unit cell lengths | 108.751, 108.751, 327.488 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 48.680 - 2.090 |
R-factor | 0.20094 |
Rwork | 0.200 |
R-free | 0.22589 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.946 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.150 |
High resolution limit [Å] | 2.090 | 2.090 |
Number of reflections | 41865 | |
Completeness [%] | 99.5 | 96.3 |
Redundancy | 7.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.9 | 293 | 2.0 M ammonium sulfate, 2% PEG400, 0.1 MES, pH 5.9, VAPOR DIFFUSION, HANGING DROP, temperature 293K |