E. coli sliding clamp in complex with AcQLDAF

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2012-10-20
DetectorMAR scanner 345 mm plate
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths79.876, 67.229, 81.192
Unit cell angles90.00, 113.95, 90.00
Refinement procedure
Resolution30.530 - 1.850
R-factor0.1994
Rwork0.197
R-free0.24240
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1mmi
RMSD bond length0.006
RMSD bond angle1.158
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.920
High resolution limit [Å]1.8503.9901.850
Rmerge0.0270.0220.229
Number of reflections66782
<I/σ(I)>30.1
Completeness [%]99.297.595.6
Redundancy3.63.63.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5285100mM MES, 100-150mM CaCl2, 25-30%(v/v) PEG400, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 285K