Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4JQ2

AKR1C2 complex with sulindac

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2012-09-29
DetectorADSC QUANTUM 315r
Wavelength(s)0.9537
Spacegroup nameH 3 2
Unit cell lengths143.165, 143.165, 204.890
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.790 - 1.750
R-factor0.1661
Rwork0.163
R-free0.22290
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)inhouse unliganded
RMSD bond length0.018
RMSD bond angle2.028
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]106.1001.840
High resolution limit [Å]1.7501.750
Number of reflections80393
Completeness [%]99.295.7
Redundancy19.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29120% PEG 3350, 0.2 M diammonium-L-tartrate, VAPOR DIFFUSION, SITTING DROP, temperature 291K

222036

PDB entries from 2024-07-03

PDB statisticsPDBj update infoContact PDBjnumon