4JN1
An Antidote for Dabigatran
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Detector technology | CCD |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.0 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 113.132, 78.217, 63.434 |
Unit cell angles | 90.00, 89.91, 90.00 |
Refinement procedure
Resolution | 40.000 - 1.890 |
R-factor | 0.1769 |
Rwork | 0.176 |
R-free | 0.19660 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.050 |
Refinement software | BUSTER (2.11.2) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 39.109 |
High resolution limit [Å] | 1.890 |
Number of reflections | 75791 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |