Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4I27

Ternary complex of mouse TdT with ssDNA and incoming nucleotide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-2
Synchrotron siteESRF
BeamlineID23-2
Temperature [K]100
Detector technologyCCD
Collection date2011-04-01
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.8726
Spacegroup nameP 1 21 1
Unit cell lengths46.940, 95.900, 47.230
Unit cell angles90.00, 107.75, 90.00
Refinement procedure
Resolution47.950 - 2.600
R-factor0.1741
Rwork0.171
R-free0.23300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1jms
RMSD bond length0.010
RMSD bond angle1.090
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.9502.740
High resolution limit [Å]2.6002.600
Rmerge0.1370.461
Number of reflections12246
<I/σ(I)>2.5
Completeness [%]99.599.9
Redundancy3.23.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP829320% PEG4000, 20% isopropanol, 100 mM sodium citrate, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24