Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE AR-NW12A |
| Synchrotron site | Photon Factory |
| Beamline | AR-NW12A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-05-01 |
| Detector | ADSC QUANTUM 210 |
| Wavelength(s) | 1.0 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 49.438, 131.126, 133.032 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 37.978 - 2.302 |
| R-factor | 0.2004 |
| Rwork | 0.198 |
| R-free | 0.24840 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3gmb |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.384 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Refinement software | PHENIX ((phenix.refine: 1.7.3_928)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.340 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.121 | 0.412 |
| Number of reflections | 18939 | |
| <I/σ(I)> | 10 | 4.8 |
| Completeness [%] | 96.5 | 100 |
| Redundancy | 7 | 7.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | 8% PEG 8000, 0.1M Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |