Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4H1P

Use of Europium for SAD Phasing at the Cu K alpha wavelength

Replaces:  4ENI
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsBRUKER AXS MICROSTAR
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2011-03-09
DetectorMAR scanner 345 mm plate
Wavelength(s)1.54
Spacegroup nameP 43 21 2
Unit cell lengths77.485, 77.485, 36.986
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.752 - 2.300
R-factor0.1795
Rwork0.174
R-free0.23090
Structure solution methodSAD
RMSD bond length0.007
RMSD bond angle1.062
Data reduction softwareAUTOMAR
Phasing softwareAutoSol
Refinement softwarePHENIX ((phenix.refine: 1.6.1_357))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.530
High resolution limit [Å]2.3002.300
Number of reflections5354
Completeness [%]99.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.5293Sodium chloride, EuCl3, sodium acetate, pH 4.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K, temperature 293.0K

218500

PDB entries from 2024-04-17

PDB statisticsPDBj update infoContact PDBjnumon