Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4GTP

FTase in complex with BMS analogue 16

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyCCD
Collection date2009-11-16
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1.0000
Spacegroup nameP 61
Unit cell lengths171.650, 171.650, 70.005
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution29.910 - 2.750
R-factor0.17922
Rwork0.177
R-free0.22565
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3eu5
RMSD bond length0.020
RMSD bond angle1.883
Data reduction softwareMOSFLM
Data scaling softwareXSCALE
Phasing softwarePHASES
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.9102.850
High resolution limit [Å]2.7502.750
Number of reflections30855
<I/σ(I)>17.85
Completeness [%]99.9100
Redundancy6.36.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.529220% (w/v) PEG 4000, 0.2M MgCl2, 0.1M Tris, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 292K

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon