Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4GKS

A2-MHC Complex carrying FLTGIGIITV

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyCCD
DetectorADSC QUANTUM 4
Wavelength(s)0.91730
Spacegroup nameC 1 2 1
Unit cell lengths201.540, 46.780, 115.860
Unit cell angles90.00, 121.66, 90.00
Refinement procedure
Resolution39.049 - 2.346
R-factor0.215
Rwork0.211
R-free0.28520
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4gkn
RMSD bond length0.015
RMSD bond angle1.664
Data reduction softwarexia2
Data scaling softwareSCALA (3.3.16)
Phasing softwarePHASER
Refinement softwareREFMAC
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]39.04939.0492.410
High resolution limit [Å]2.34610.4902.346
Rmerge0.0460.701
Total number of observations157810780
Number of reflections36005
<I/σ(I)>8.812.41
Completeness [%]92.492.194.2
Redundancy43.64
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.529325% PEG 8000, 200 mM Ammonium Sulphate, 200 mM Cacodylate Buffer, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K

227111

PDB entries from 2024-11-06

PDB statisticsPDBj update infoContact PDBjnumon