4GJS
Streptavidin-K121H
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-06-03 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.0000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 81.652, 81.331, 47.002 |
Unit cell angles | 90.00, 104.83, 90.00 |
Refinement procedure
Resolution | 28.321 - 1.850 |
R-factor | 0.205 |
Rwork | 0.203 |
R-free | 0.25000 |
Structure solution method | MOLECULAR REPLACEMENT |
Data scaling software | SCALA (CCP4_3.3.20 2011/05/18) |
Refinement software | PHENIX (dev_1050) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 40.670 | 40.670 | 1.950 |
High resolution limit [Å] | 1.850 | 5.850 | 1.850 |
Rmerge | 0.081 | 0.100 | 0.180 |
Total number of observations | 2216 | 7608 | |
Number of reflections | 24972 | ||
<I/σ(I)> | 5.9541 | 5.55 | 3.55 |
Completeness [%] | 98.5 | 94.75 | 96.35 |
Redundancy | 2.65 | 2.84 | 2.14 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 277 | 0.1 M MES, 19 % PEG500, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K |