Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4G01

ARA7-GDP-Ca2+/VPS9a

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE AR-NW12A
Synchrotron sitePhoton Factory
BeamlineAR-NW12A
Temperature [K]100
Detector technologyCCD
Collection date2009-11-18
DetectorADSC QUANTUM 210
Wavelength(s)1.0000
Spacegroup nameP 21 21 21
Unit cell lengths68.349, 76.139, 81.787
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution55.730 - 2.200
R-factor0.20173
Rwork0.198
R-free0.27282
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2efc
RMSD bond length0.013
RMSD bond angle1.374
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareAMoRE
Refinement softwareREFMAC (5.5.0088)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]55.7302.240
High resolution limit [Å]2.2002.200
Number of reflections22345
<I/σ(I)>15.82.8
Completeness [%]99.999.8
Redundancy7.27
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.529320% PEG3350, 200mM calcium acetate, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon