4EKV
Streptavidin 8-aa-loop H127C mutein with reversible biotin binding
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RUH3R |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2010-12-07 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.5418 |
Spacegroup name | P 42 21 2 |
Unit cell lengths | 57.066, 57.066, 70.186 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.390 - 2.000 |
R-factor | 0.1902 |
Rwork | 0.188 |
R-free | 0.22520 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1swe |
RMSD bond length | 0.009 |
RMSD bond angle | 1.265 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.020 |
High resolution limit [Å] | 1.950 | 1.950 |
Rmerge | 0.063 | 0.496 |
Number of reflections | 8607 | |
<I/σ(I)> | 28.4 | 2.8 |
Completeness [%] | 96.1 | 88 |
Redundancy | 6.7 | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 298 | 50% Tacsimate, 10% glycerol, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |