4AYB

RNAP at 3.2Ang

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]110
Detector technologyCCD
Collection date2009-11-06
DetectorMARMOSAIC 225 mm CCD
Spacegroup nameP 21 21 2
Unit cell lengths195.725, 212.415, 128.757
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.097 - 3.202
R-factor0.2454
Rwork0.242
R-free0.30050
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2waq
RMSD bond length0.007
RMSD bond angle0.762
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.1003.270
High resolution limit [Å]3.2003.200
Rmerge0.180
Number of reflections88449
<I/σ(I)>13.92
Completeness [%]99.599.1
Redundancy15.215.3