4AHV
Parallel screening of a low molecular weight compound library: do differences in methodology affect hit identification
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-04-25 |
| Detector | ADSC QUANTUM 210r |
| Spacegroup name | P 31 |
| Unit cell lengths | 70.923, 70.923, 66.690 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 61.430 - 1.800 |
| R-factor | 0.17736 |
| Rwork | 0.175 |
| R-free | 0.22377 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4ahr |
| RMSD bond length | 0.023 |
| RMSD bond angle | 2.194 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 61.400 | 1.900 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmerge | 0.080 | 0.820 |
| Number of reflections | 33604 | |
| <I/σ(I)> | 12.3 | 1.1 |
| Completeness [%] | 96.6 | 81.3 |
| Redundancy | 3.9 | 2.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293 | PROTEIN: 5.5MG/ML IN 40 MM TRIS BUFFER AT PH 8.0, 250 MM NACL, 30 MM MGCL2, 5MM DTT. CRYSTALLANT: 100 MM SODIUM ACETATE PH 5.0 TO 5.5, 1.2 TO 1.5 M AMMONIUM SULFATE AT 20C IN SITTING DROP PLATES. FRAGMENTS WERE SOAKED INTO PREFORMED CRYSTALS 24-48 HOURS PRIOR TO DATA COLLECTION. |