4A93
RNA Polymerase II elongation complex containing a CPD Lesion
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2008-02-08 |
Detector | DECTRIS PILATUS 6M |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 221.637, 391.519, 281.774 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 54.093 - 3.400 |
R-factor | 0.1656 |
Rwork | 0.165 |
R-free | 0.19890 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1wcm |
RMSD bond length | 0.011 |
RMSD bond angle | 1.498 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 54.000 | 3.580 |
High resolution limit [Å] | 3.400 | 3.400 |
Rmerge | 0.120 | 0.790 |
Number of reflections | 167266 | |
<I/σ(I)> | 10.7 | 2.3 |
Completeness [%] | 100.0 | 100 |
Redundancy | 7 | 6.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |