4ZH1
Complement factor H in complex with the GM1 glycan
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-11-25 |
Detector | DECTRIS PILATUS 2M-F |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 |
Unit cell lengths | 75.770, 82.860, 86.570 |
Unit cell angles | 112.97, 111.43, 99.63 |
Refinement procedure
Resolution | 46.180 - 2.240 |
R-factor | 0.18326 |
Rwork | 0.181 |
R-free | 0.22835 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3oxu |
RMSD bond length | 0.012 |
RMSD bond angle | 1.387 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0049) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.300 |
High resolution limit [Å] | 2.240 | 2.240 |
Rmerge | 0.052 | 0.611 |
Number of reflections | 79286 | |
<I/σ(I)> | 15.6 | 1.99 |
Completeness [%] | 97.6 | 97.1 |
Redundancy | 3.5 | 3.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | 0.1 M TRIS-HCL, PH 9.0, 8% W/V PRG 8000 |