4Y19
immune complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 110 |
| Detector technology | CCD |
| Collection date | 2013-08-21 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.954 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 115.760, 152.740, 153.090 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 36.600 | 2.590 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmerge | 0.137 | 0.629 |
| Number of reflections | 47168 | |
| <I/σ(I)> | 12.7 | 3.8 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 8.1 | 3.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6 | 293 | 100 mM MES pH 6.0, 2 M ammonium sulfate and 0.2 M sodium malonate |