Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4XVB

Recombinant thaumatin in the presence of 1.5M PST at 293K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL26B1
Synchrotron siteSPring-8
BeamlineBL26B1
Temperature [K]293
Detector technologyCCD
Collection date2014-10-12
DetectorRIGAKU SATURN A200
Wavelength(s)1.00
Spacegroup nameP 41 21 2
Unit cell lengths58.487, 58.487, 151.609
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution27.942 - 1.520
R-factor0.1099
Rwork0.109
R-free0.12960
RMSD bond length0.006
RMSD bond angle1.100
Data scaling softwareHKL-2000
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.550
High resolution limit [Å]1.5201.520
Rmerge0.0530.468
Number of reflections41551
<I/σ(I)>68.988.05
Completeness [%]100.0100
Redundancy14.314.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP72930.05 M ADA, 1.5M K-Na TARTRATE

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon