4WK8
FOXP3 forms a domain-swapped dimer to bridge DNA
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.1 |
| Synchrotron site | ALS |
| Beamline | 8.2.1 |
| Temperature [K] | 93 |
| Detector technology | CCD |
| Collection date | 2009-05-10 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 81.431, 84.837, 68.310 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 44.541 - 3.401 |
| R-factor | 0.1964 |
| Rwork | 0.190 |
| R-free | 0.25250 |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.569 |
| Refinement software | PHENIX ((phenix.refine: 1.8.4_1496)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 3.400 |
| Number of reflections | 7159 |
| <I/σ(I)> | 10.6 |
| Completeness [%] | 93.9 |
| Redundancy | 5.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291 | PEG 8000 |