Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4WFG

Human TRAAK K+ channel in a Tl+ bound conductive conformation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2014-04-19
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9781
Spacegroup nameP 1 21 1
Unit cell lengths80.798, 138.760, 96.317
Unit cell angles90.00, 94.52, 90.00
Refinement procedure
Resolution48.000 - 3.000
R-factor0.20395
Rwork0.202
R-free0.23630
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4i9w
RMSD bond length0.006
RMSD bond angle0.898
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.0003.050
High resolution limit [Å]3.0003.000
Number of reflections40099
<I/σ(I)>14.70.9
Completeness [%]99.699.7
Redundancy5.65.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.827750 MM TRIS PH 8.8, 200 MM CA(NO3)2, 27-30%(VOL/VOL) PEG400, 52 MM TRICHLOROETHANOL

219869

PDB entries from 2024-05-15