4RYF
ClpP1/2 heterocomplex from Listeria monocytogenes
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2014-07-19 |
| Detector | PSI PILATUS 6M |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 97.230, 127.150, 265.500 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.900 |
| High resolution limit [Å] | 2.800 | 2.800 |
| Rmerge | 0.096 | 0.480 |
| Number of reflections | 78792 | |
| <I/σ(I)> | 14.2 | 3.5 |
| Completeness [%] | 96.2 | 98.1 |
| Redundancy | 4.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 0.2 M Sodium-Malonate, 40% MPD, pH 7.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K |