4POY
Engineered Dual Specific VHH antibody
Experimental procedure
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-BM |
| Synchrotron site | APS |
| Beamline | 22-BM |
| Detector technology | CCD |
| Collection date | 2010-06-15 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 1.00 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 53.753, 61.979, 64.803 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.380 - 1.500 |
| R-factor | 0.20259 |
| Rwork | 0.201 |
| R-free | 0.24123 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.016 |
| RMSD bond angle | 1.516 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 1.300 |
| Rmerge | 0.038 |
| Number of reflections | 191128 |
| Completeness [%] | 99.8 |
| Redundancy | 7.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 298.15 | 0.1 M Bis-Tris, 2.0 M Ammonium Sulfate, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 298.15K |