4PKT
Anthrax toxin lethal factor with bound small molecule inhibitor 13
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-03-15 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 57.530, 76.807, 139.334 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.360 - 2.400 |
R-factor | 0.1815 |
Rwork | 0.178 |
R-free | 0.23990 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.117 |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 139.334 |
High resolution limit [Å] | 2.400 |
Rmerge | 0.100 |
Number of reflections | 24878 |
<I/σ(I)> | 13.4 |
Completeness [%] | 100.0 |
Redundancy | 6.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 286 | 11-16% PEG 8K, 50 mM Bis-Tris, 100 mM magnesium acetate |