4NYT
L-Ficolin Complexed to Phosphocholine
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-07-02 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97887 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 96.130, 96.130, 139.880 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.950 - 2.250 |
R-factor | 0.21439 |
Rwork | 0.213 |
R-free | 0.24293 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.018 |
RMSD bond angle | 1.898 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0032) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 20.000 | 20.000 | 2.260 |
High resolution limit [Å] | 2.200 | 9.840 | 2.200 |
Number of reflections | 38356 | ||
Completeness [%] | 99.5 | 80.9 | 99.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7 | 293 | 15%(w/v) PEG 8000, 200mM Ca acetate, 0.1M Hepes, pH 7.0, VAPOR DIFFUSION, temperature 293K |