Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4HFB

The GLIC pentameric Ligand-Gated Ion Channel F14'A ethanol-sensitive mutant (Apo)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyPIXEL
Collection date2011-09-20
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9801
Spacegroup nameC 1 2 1
Unit cell lengths183.737, 133.512, 161.120
Unit cell angles90.00, 103.28, 90.00
Refinement procedure
Resolution30.000 - 2.750
R-factor0.2085
Rwork0.208
R-free0.22230
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.080
Data reduction softwareXDS
Data scaling softwareSCALA
Refinement softwareBUSTER (2.11.2)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]48.60048.6302.900
High resolution limit [Å]2.7508.6902.750
Rmerge0.0440.0180.630
Number of reflections97187
<I/σ(I)>15.650.62
Completeness [%]98.897.396.7
Redundancy3.43.23.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP429112-15% PEG4K, 0.1M Na Acetate 0.4M NaSCN, VAPOR DIFFUSION, HANGING DROP, temperature 291K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon