Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4GRQ

Characterization of N- and C- terminus mutants of human MIF

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X25
Synchrotron siteNSLS
BeamlineX25
Temperature [K]100
Detector technologyPIXEL
Collection date2011-12-10
DetectorPSI PILATUS 6M
Spacegroup nameP 31 2 1
Unit cell lengths95.369, 95.369, 103.830
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.680 - 1.650
R-factor0.139
Rwork0.137
R-free0.16100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)MIF
RMSD bond length0.020
RMSD bond angle1.748
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.720
High resolution limit [Å]1.4701.650
Rmerge0.0850.555
Number of reflections93378
<I/σ(I)>26.75.4
Completeness [%]99.998.4
Redundancy11.217.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
16.53101.6M ammonium sulfate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 310K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon