Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3VXT

T36-5 TCR specific for HLA-A24-Nef134-10

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL41XU
Synchrotron siteSPring-8
BeamlineBL41XU
Temperature [K]100
Detector technologyCCD
Collection date2010-10-29
DetectorRAYONIX MX225HE
Wavelength(s)1.0000
Spacegroup nameP 1
Unit cell lengths45.768, 65.036, 92.275
Unit cell angles91.30, 94.19, 105.93
Refinement procedure
Resolution50.000 - 2.500
Rwork0.230
R-free0.27100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3kxf
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareCNS (1.3)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.590
High resolution limit [Å]2.5005.3802.500
Rmerge0.0280.222
Number of reflections32447
<I/σ(I)>23.5
Completeness [%]91.993.781.6
Redundancy33.71.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP62930.2M potassium sulfate, 0.1M MES, 15% PEG8000, pH 6.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K

223166

PDB entries from 2024-07-31