3VQH
Bromine SAD partially resolves multiple binding modes for PKA inhibitor H-89
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID29 |
| Synchrotron site | ESRF |
| Beamline | ID29 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-12-11 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.91969 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 72.730, 75.180, 80.330 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 33.390 - 1.950 |
| R-factor | 0.19203 |
| Rwork | 0.190 |
| R-free | 0.23395 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ydt |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.382 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.200 |
| High resolution limit [Å] | 1.730 | 1.950 |
| Number of reflections | 32645 | |
| <I/σ(I)> | 19.08 | 5.68 |
| Completeness [%] | 99.3 | 98 |
| Redundancy | 4.6 | 4.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.9 | 277 | 10mg/ml protein, 25mM BisTris/MES pH6.9, 50mM KCl, 1.5mM octanoyl-N-methylglucamide, 1mM Protein kinase inhibitor peptide, 5mM H-89 in MeOH', VAPOR DIFFUSION, HANGING DROP, temperature 277K |