Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

3UU6

The GLIC pentameric Ligand-Gated Ion Channel Loop2-22' mutant reduced in solution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2011-02-25
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9537
Spacegroup nameC 1 2 1
Unit cell lengths181.090, 133.050, 159.310
Unit cell angles90.00, 101.78, 90.00
Refinement procedure
Resolution26.650 - 2.980
R-factor0.2315
Rwork0.231
R-free0.24130
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3eam
RMSD bond length0.010
RMSD bond angle1.120
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareBUSTER (2.11.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.5003.150
High resolution limit [Å]2.9802.980
Rmerge0.0610.567
Number of reflections74738
<I/σ(I)>132.2
Completeness [%]99.699.6
Redundancy3.43.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP429315% PEG4000, 0.4 M sodium thiocyanate, 0.1 M sodium acetate, pH 4.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K

238895

PDB entries from 2025-07-16

PDB statisticsPDBj update infoContact PDBjnumon