3UBV
Oxygen-bound hell's gate globin I by classical hanging drop
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-4 |
Synchrotron site | ESRF |
Beamline | ID14-4 |
Detector technology | CCD |
Collection date | 2011-09-30 |
Detector | ADSC QUANTUM 315r |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 70.350, 126.510, 148.360 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 74.180 - 3.200 |
R-factor | 0.22659 |
Rwork | 0.223 |
R-free | 0.29979 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.014 |
RMSD bond angle | 1.550 |
Data reduction software | MOSFLM |
Data scaling software | SCALA (3.3.16) |
Phasing software | MOLREP |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 74.180 | 48.132 | 3.370 |
High resolution limit [Å] | 3.200 | 10.120 | 3.200 |
Rmerge | 0.202 | 0.354 | |
Number of reflections | 11288 | ||
<I/σ(I)> | 5.6 | 2.5 | 1.5 |
Completeness [%] | 99.9 | 99.1 | 100 |
Redundancy | 6.4 | 6.1 | 6.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | VAPOR DIFFUSION, HANGING DROP |