3TV7
Human Rho-associated protein kinase 1 (ROCK 1) in COMPLEX WITH RKI1342
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 93 |
| Detector technology | CCD |
| Collection date | 2011-08-26 |
| Detector | RIGAKU SATURN 944+ |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 151.010, 150.920, 185.570 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.828 - 2.750 |
| Rwork | 0.205 |
| R-free | 0.25330 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | CHAIN A OF 2ETR |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.329 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((phenix.refine: 1.7_650)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.800 |
| High resolution limit [Å] | 2.750 | 2.750 |
| Rmerge | 0.070 | 0.300 |
| Number of reflections | 55039 | |
| <I/σ(I)> | 20 | 5.8 |
| Completeness [%] | 99.9 | 100 |
| Redundancy | 7.4 | 7.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.4 | 292 | 10 mg/ml ROCK1, 75 mm hepes pH 7.4, 2.5 % tacsimate ph 7.4, 5 % PEG 5000 MME, VAPOR DIFFUSION, SITTING DROP, temperature 292K |