Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3TNH

CDK9/cyclin T in complex with CAN508

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]100
Detector technologyPIXEL
Collection date2011-07-23
DetectorPSI PILATUS 6M
Wavelength(s)0.9778
Spacegroup nameH 3
Unit cell lengths173.300, 173.300, 97.220
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution38.265 - 3.202
R-factor0.1791
Rwork0.177
R-free0.22570
Structure solution methodRigid body refinement
Starting model (for MR)3blh
RMSD bond length0.013
RMSD bond angle1.526
Data reduction softwareXDS
Data scaling softwarexia2
Phasing softwarePHENIX
Refinement softwarePHENIX ((phenix.refine: 1.7.1_743))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]49.00049.0003.290
High resolution limit [Å]3.20014.3203.200
Rmerge0.0160.537
Number of reflections17892
<I/σ(I)>41.20.8
Completeness [%]99.896.399.9
Redundancy3.43.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.227714% PEG 1K, 100mM Na K phosphate, 600mM NaCl, 4mM TCEP, pH 6.2, VAPOR DIFFUSION, SITTING DROP, temperature 277K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon