3R8H
AKR1C3 complex with zomepirac
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-03-14 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.979417 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 57.294, 64.035, 95.983 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.500 - 1.900 |
R-factor | 0.16631 |
Rwork | 0.164 |
R-free | 0.20430 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2fgb |
RMSD bond length | 0.026 |
RMSD bond angle | 2.013 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.580 | 2.000 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.109 | 0.705 |
Number of reflections | 28113 | |
<I/σ(I)> | 21.2 | 4.9 |
Completeness [%] | 98.7 | 98.1 |
Redundancy | 14.6 | 14.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |