3Q19
Human Glutathione Transferase O2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-01-01 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.95663 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 46.425, 85.017, 60.397 |
Unit cell angles | 90.00, 94.55, 90.00 |
Refinement procedure
Resolution | 42.510 - 1.900 |
R-factor | 0.165 |
Rwork | 0.164 |
R-free | 0.19418 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1eem |
RMSD bond length | 0.009 |
RMSD bond angle | 1.133 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.510 | 2.000 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.054 | 0.155 |
Number of reflections | 34258 | |
<I/σ(I)> | 10.5 | 3.9 |
Completeness [%] | 92.9 | 85.2 |
Redundancy | 5.9 | 5.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 9 | 291 | 0.1M sodium chloride, 0.1M Bicine pH 9.0, 20% (v/v) PEGMME 2000, VAPOR DIFFUSION, HANGING DROP, temperature 291K |