Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-10-01 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.2398 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 42.437, 69.122, 69.024 |
Unit cell angles | 90.00, 105.44, 90.00 |
Refinement procedure
Resolution | 19.171 - 2.400 |
R-factor | 0.1973 |
Rwork | 0.195 |
R-free | 0.24290 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1z2w |
RMSD bond length | 0.009 |
RMSD bond angle | 1.146 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.6.1_357)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 19.610 |
High resolution limit [Å] | 2.400 |
Number of reflections | 14590 |
Completeness [%] | 99.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.6 | 289 | 0.1M Tris, 0.2M NaCl, 20% PEG 3350, pH 8.6, VAPOR DIFFUSION, SITTING DROP, temperature 289K |