Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3OS9

Estrogen Receptor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL11-1
Synchrotron siteSSRL
BeamlineBL11-1
Wavelength(s)0.9764
Spacegroup nameP 1
Unit cell lengths52.904, 59.058, 93.761
Unit cell angles86.64, 74.64, 63.43
Refinement procedure
Resolution20.000 - 2.303
R-factor0.207
Rwork0.205
R-free0.24910
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.002
RMSD bond angle0.670
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((phenix.refine))
Data quality characteristics
 Overall
Low resolution limit [Å]20.000
High resolution limit [Å]2.303
Number of reflections39541
Completeness [%]91.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8298see publication, pH 8, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon