3O7O
Use of synthetic symmetrization in the crystallization and structure determination of CelA from Thermotoga maritima
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-04-25 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9794 |
Spacegroup name | P 63 |
Unit cell lengths | 114.028, 114.028, 98.818 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 20.180 - 2.410 |
R-factor | 0.1776 |
Rwork | 0.176 |
R-free | 0.21570 |
Structure solution method | SAD |
RMSD bond length | 0.009 |
RMSD bond angle | 1.100 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | SHELX |
Refinement software | BUSTER-TNT |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 98.750 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.084 | 0.450 |
Number of reflections | 27835 | |
<I/σ(I)> | 5.6 | 2 |
Completeness [%] | 97.0 | 85.7 |
Redundancy | 5.8 | 5.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.3 | 295 | 0.2 M NaBr, 0.1 M TRIS-HCl pH 8.3, 42% MPD, VAPOR DIFFUSION, HANGING DROP, temperature 295K |
1 | VAPOR DIFFUSION, HANGING DROP | 8.3 | 295 | 0.2 M NaBr, 0.1 M TRIS-HCl pH 8.3, 42% MPD, VAPOR DIFFUSION, HANGING DROP, temperature 295K |