3O29
Ligand-binding domain of GluA2 (flip) ionotropic glutamate receptor in complex with an allosteric modulator
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID14-3 |
| Synchrotron site | ESRF |
| Beamline | ID14-3 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2005-07-04 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 0.931 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 64.127, 88.518, 47.336 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 25.000 - 2.020 |
| R-factor | 0.17391 |
| Rwork | 0.170 |
| R-free | 0.24977 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.018 |
| RMSD bond angle | 1.845 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | REFMAC (5.2.0005) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 25.000 | 2.070 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Rmerge | 0.071 | 0.409 |
| Number of reflections | 17620 | |
| <I/σ(I)> | 16.4 | 2.5 |
| Completeness [%] | 96.5 | 81.7 |
| Redundancy | 3.4 | 2.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.5 | 277 | 12% PEG 4000, 100mM Sodium Cacodylate pH 4.5, 50mM Lithium Sulphate, VAPOR DIFFUSION, HANGING DROP, temperature 277K |