3NHC
GYMLGS segment 127-132 from human prion with M129
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-11-19 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 1.0048 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 18.150, 9.553, 45.163 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 22.580 - 1.570 |
R-factor | 0.2246 |
Rwork | 0.221 |
R-free | 0.25280 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.013 |
RMSD bond angle | 1.541 |
Data scaling software | SCALEPACK |
Phasing software | PHASER (1.3.2) |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 90.000 | 90.000 | 1.610 |
High resolution limit [Å] | 1.550 | 3.340 | 1.550 |
Rmerge | 0.186 | 0.137 | 0.398 |
Number of reflections | 1163 | ||
<I/σ(I)> | 9.4 | ||
Completeness [%] | 90.9 | 96.8 | 78.2 |
Redundancy | 5.4 | 4.8 | 5.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | 0.2M Tris pH 7.0, vapor diffusion, hanging drop, temperature 298K |