3M8P
HIV-1 RT with NNRTI TMC-125
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-09-25 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.0000 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 118.441, 153.533, 154.615 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.010 - 2.670 |
R-factor | 0.21243 |
Rwork | 0.209 |
R-free | 0.28289 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.028 |
RMSD bond angle | 2.159 |
Data reduction software | XDS |
Data scaling software | XDS |
Refinement software | REFMAC (5.5.0072) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.290 |
Rmerge | 0.309 |
Number of reflections | 49129 |
Completeness [%] | 77.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.2 | 293 | 1.4 M Na Malonate, 50mM KPO4 pH 7.2, 5% Ethylene Glycol, VAPOR DIFFUSION, SITTING DROP, temperature 293K |