3LX9
Interconversion of Human Lysosomal Enzyme Specificities
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-12-15 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.07188 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 89.947, 139.492, 182.580 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.690 - 2.040 |
R-factor | 0.178 |
Rwork | 0.176 |
R-free | 0.21800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3hg3 |
RMSD bond length | 0.005 |
RMSD bond angle | 1.056 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC (5.5.0070) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.090 |
High resolution limit [Å] | 2.040 | 2.040 |
Rmerge | 0.120 | 0.701 |
Number of reflections | 72009 | |
<I/σ(I)> | 18.6 | 1.6 |
Completeness [%] | 99.4 | 93.3 |
Redundancy | 6.7 | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | PEG8000, Sodium Cacodylate, Magnesium Acetate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |