3HPL

KcsA E71H-F103A mutant in the closed state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Detector technologyCCD
Collection date2008-12-01
DetectorADSC QUANTUM 315
Wavelength(s)1.0
Spacegroup nameI 4
Unit cell lengths156.140, 156.140, 76.292
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.000 - 3.200
Rwork0.220
R-free0.26910
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.440
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 Overall
Low resolution limit [Å]40.000
High resolution limit [Å]3.200
Number of reflections12699
Completeness [%]90.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29820-25% PEG 400, 50 mM magnesium acetate, 50 mM sodium acetate, pH 5.0-6.0, VAPOR DIFFUSION, SITTING DROP, temperature 298K