Voltage-dependent K+ channel beta subunit (I211R) in complex with cortisone

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X4C
Synchrotron siteNSLS
BeamlineX4C
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2007-08-26
DetectorMAR scanner 345 mm plate
Wavelength(s)0.97893
Spacegroup nameI 4 2 2
Unit cell lengths113.260, 113.260, 147.266
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.040 - 2.000
R-factor0.223
Rwork0.223
R-free0.25600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1exb chain A beta subunit
RMSD bond length0.007
RMSD bond angle1.200
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.020
High resolution limit [Å]1.9501.950
Rmerge0.0640.460
Number of reflections35198
<I/σ(I)>35.664.48
Completeness [%]100.0100
Redundancy10.69.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2936-15% glycerol, 1.5 M ammonium sulfate, 0.1 M Tris, VAPOR DIFFUSION, SITTING DROP, temperature 293K

218853

PDB entries from 2024-04-24