Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

3EB3

Voltage-dependent K+ channel beta subunit (W121A) in complex with cortisone

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X4A
Synchrotron siteNSLS
BeamlineX4A
Temperature [K]100
Detector technologyCCD
Collection date2007-06-22
DetectorADSC QUANTUM 4
Wavelength(s)0.97935
Spacegroup nameI 4 2 2
Unit cell lengths113.198, 113.198, 146.691
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.890 - 2.000
R-factor0.222
Rwork0.222
R-free0.24900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1exb chain A beta subunit
RMSD bond length0.007
RMSD bond angle1.100
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.070
High resolution limit [Å]2.0002.000
Rmerge0.0540.314
Number of reflections32564
<I/σ(I)>52.49.3
Completeness [%]99.0100
Redundancy13.311.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2936-15% glycerol, 1.5 M ammonium sulfate, 0.1 M Tris, VAPOR DIFFUSION, SITTING DROP, temperature 293K

237735

PDB entries from 2025-06-18