3D27
E. coli methionine aminopeptidase with Fe inhibitor W29
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Detector technology | IMAGE PLATE |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.5418 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 38.510, 59.880, 54.880 |
Unit cell angles | 90.00, 106.47, 90.00 |
Refinement procedure
Resolution | 26.860 - 2.200 |
R-factor | 0.193 |
Rwork | 0.191 |
R-free | 0.24400 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.065 |
Data reduction software | MOSFLM |
Data scaling software | SCALA (3.2.25) |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 59.880 | 39.530 | 2.320 |
High resolution limit [Å] | 2.200 | 6.960 | 2.200 |
Rmerge | 0.070 | 0.052 | 0.216 |
Total number of observations | 1494 | 6819 | |
Number of reflections | 12282 | ||
<I/σ(I)> | 8.4 | 11 | 3.3 |
Completeness [%] | 100.0 | 99.7 | 100 |
Redundancy | 3.9 | 3.6 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 100 mM MES (pH 6.5), 2 mM MnCl2, 17% PEG 20000, vapor diffusion, hanging drop, temperature 298K |