3CVH
How TCR-like antibody recognizes MHC-bound peptide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X4A |
Synchrotron site | NSLS |
Beamline | X4A |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-09-01 |
Detector | ADSC QUANTUM 4 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 80.570, 111.345, 219.087 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.980 - 2.900 |
R-factor | 0.223 |
Rwork | 0.219 |
R-free | 0.29600 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | PDB ENTRIES 3CVI AND 2VAA |
RMSD bond length | 0.008 |
RMSD bond angle | 1.089 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.900 |
High resolution limit [Å] | 2.800 | 2.800 |
Rmerge | 0.429 | |
Number of reflections | 48272 | |
Completeness [%] | 97.6 | 95 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 4.6 | 293 | 0.2 M (NH4)2SO4, 0.1 M NaOAc, pH 4.6 containing 25% w/v polyethylene glycol 4000, VAPOR DIFFUSION, HANGING DROP, temperature 293K |