3CU8
Impaired binding of 14-3-3 to Raf1 is linked to Noonan and LEOPARD syndrome
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-08-25 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.97809 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 72.400, 83.840, 111.650 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 15.000 - 2.400 |
R-factor | 0.19192 |
Rwork | 0.188 |
R-free | 0.25901 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.021 |
RMSD bond angle | 1.972 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC (5.4.0067) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 15.000 | 2.500 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.052 | 0.416 |
Number of reflections | 27180 | |
<I/σ(I)> | 4.02 | |
Completeness [%] | 99.8 | 100 |
Redundancy | 4.95 | 5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 0.1M (Sodium propionate, sodium cacodylate, BIS-TRIS propane), 27% PEG 1500, 2mM DTT, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |