3AL7

Recombinant thaumatin I at 1.1 A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL38B1
Synchrotron siteSPring-8
BeamlineBL38B1
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2009-04-18
DetectorRIGAKU RAXIS V
Spacegroup nameP 41 21 2
Unit cell lengths57.699, 57.699, 149.776
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution10.000 - 1.100
R-free0.13540
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rqw
RMSD bond length0.017
RMSD bond angle0.034
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSHELX
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.140
High resolution limit [Å]1.1001.100
Rmerge0.0840.368
Number of reflections102055
<I/σ(I)>27.692.2
Completeness [%]98.990.8
Redundancy6.54.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.52930.02M ADA, 0.75M TARTRATE. 20%GLYCEROL, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon